Motor-Driven Metering Pump Sigma/ 1 (Basic type)

Capacity range 17 – 144 l/h, 12 – 4 bar

The Sigma/ 1 Basic is an extremely robust motor-driven metering pump with patented multi-layer safety diaphragm for excellent process reliability. It offers a wide range of power end designs, such as three-phase or 1-phase AC motors, also for use in areas at risk from explosion.

The Robust Pump for Safe and Reliable Use

The Sigma/ 1 diaphragm metering pump, together with pumps of type Sigma/ 2 and Sigma/ 3, represents an integrated product range. They cover the capacity range from 17 to 1,030 l/h, with a consistent operating concept, control concept and spare parts management. A wide range of power end versions is available, including some for use in areas at risk from explosion.

Your benefits

Excellent process reliability:

  • In the event of an accident, the feed chemical does not escape to the outside nor into the pump’s power end, thanks to the patented multi-layer safety diaphragm with optical (optionally electric) signalling.
  • Integrated relief valve protects the pump against overload and bleed option during the suction process ensures reliable operation.

Flexible adaptation to the process:

  • The entire Sigma product range is available as standard in a ‘Physiologically safe in respect of wetted materials’ design.
  • Metering pumps with electro-polished stainless steel metering head enable them to be used in hygienically challenging applications.
  • Adaptation to specific installation situations, as the ‘Liquid end on left’ option can be selected as standard.
  • Wide range of power end versions, also for use in ATEX areas and different flange designs for the use of customised motors.

Technical Details

  • Stroke length: 4 mm
  • Stroke length adjustment range: 0 – 100%
  • Stroke length adjustment: manually using self-locking rotary dial in 1% increments (optionally with actuator or control drive)
  • With the right, constant conditions, correct installation and calibration, precision exceeds ±1 %, based on maximum stroke volume.
  • Wetted materials: PVDF, stainless steel 1.4571/1.4404, special materials on request
  • Patented multi-layer safety diaphragm with optical diaphragm rupture display (as option with diaphragm rupture warning system via a contact)
  • Integrated hydraulic relief and bleed valve
  • A wide range of power end versions is available: Three-phase standard AC motor, 1-phase AC motor, motors for use in areas at risk from explosion and different flange designs for use in customer-specific motors
  • For areas at risk from explosion II 2G Ex h IIC T3 Gb X or II 2G Ex h IIC T4 Gb X (optional)
  • IP 55 degree of protection
  • Fibreglass-reinforced plastic housing
  • Liquid end on left is available as standard
  • For reasons of safety, provide suitable overflow devices during installation for all mechanically deflected diaphragm metering pumps

Technical Data

Type Capacity at max. back pressure with 1500 rpm motor at 50 Hz Pump capacity at max. back pressure with 1800 rpm motor at 60 Hz Suction lift Perm. pre-pressure suction side Connector Suction/Discharge Side Shipping weight
Max. stroke rate Max. stroke rate
S1Ba l/h bar ml/stroke Strokes/min l/h / gph (US) psi Strokes/min m WC bar G-DN kg
12017 PVT 17 10 3.8 73 20.4/5.3 145 88 7 1 3/4–10 9
12017 SST 17 12 3.8 73 20.4/5.3 145 88 7 1 3/4–10 12
12035 PVT 35 10 4.0 143 42.0/11.0 145 172 7 1 3/4–10 9
12035 SST 35 12 4.0 143 42.0/11.0 174 172 7 1 3/4–10 12
10050 PVT 50 10 4.0 205 60.0/15.8 145 246 7 1 3/4–10 9
10050 SST 50 10 4.0 205 60.0/15.8 145 246 7 1 3/4–10 12
10022 PVT 22 10 5.0 73 26.4/6.9 145 88 6 1 3/4–10 9
10022 SST 22 10 5.0 73 26.4/6.9 145 88 6 1 3/4–10 12
10044 PVT 44 10 5.1 143 52.8/13.9 145 172 6 1 3/4–10 9
10044 SST 44 10 5.1 143 52.8/13.9 145 172 6 1 3/4–10 12
07065 PVT 65 7 5.2 205 78.0/20.6 102 246 6 1 3/4–10 9
07065 SST 65 7 5.2 205 78.0/20.6 102 246 6 1 3/4–10 12
07042 PVT 42 7 9.5 73 50.4/13.3 102 88 3 1 1–15 10
07042 SST 42 7 9.5 73 50.4/13.3 102 88 3 1 1–15 14
04084 PVT 84 4 9.7 143 100.8/26.6 58 172 3 1 1–15 10
04084 SST 84 4 9.7 143 100.8/26.6 58 172 3 1 1–15 14
04120 PVT 120 4 9.7 205 144.0/38.0 58 246 3 1 1–15 10
04120 SST 120 4 9.7 205 144.0/38.0 58 246 3 1 1–15 14

Performance data for TTT, see type PVT

Integrated relief valve, connector for DN 10 pressure hose sleeve

Materials in Contact with the Medium

Identity code of material Dosing head Connection on suction/discharge side Seals/ball seat Balls Integral relief valve
* Specifically for areas at risk from explosion
PVT PVDF PVDF PTFE/PTFE Ceramic PVDF/FKM or EPDM
SST Stainless steel 1.4404 Stainless steel 1.4581 PTFE/PTFE Stainless steel 1.4404 Stainless steel/FKM or EPDM
TTT * PTFE + 25% carbon Carbon-filled PTFE PTFE/PTFE Ceramic
PVF PVDF PVDF PTFE/PTFE Ceramic PVDF/FKM or EPDM
SSF Stainless steel 1.4404 Stainless steel 1.4581 PTFE/PTFE Stainless steel 1.4404 Stainless steel/FKM or EPDM
SSG Stainless steel 1.4404 Stainless steel 1.4581 PTFE/stainless steel 1.4404 Stainless steel 1.4404
SSH Stainless steel 1.4435 Stainless steel 1.4435 EPDM or FKM/stainless steel 1.4435 Ceramic

Motor Data

Identity code specification Power supply Δ/Y Remarks
S 3-phase, IP 55* 230 V/400 V 50 Hz 0.09 kW
T 3-phase, IP 55* 230 V/400 V
265 V/460 V
50 Hz
60 Hz
0.09 kW
0.09 kW
With PTC, speed control range 1:5
R 3-phase, IP 55* 230 V/400 V 50 Hz 0.09 kW With PTC, speed control range 1:20 with external fan (1-phase 230 V; 50/60 Hz, 20 W)
M 1-phase AC, IP 55 230 V ± 5 % 50 Hz 0.12 kW
N 1-phase AC, IP 55 120 V ± 5 % 60 Hz 0.12 kW
L1 3-phase, II2GExellT3 220 – 240 V/380 – 420 V 50 Hz 0.12 kW
L2 3-phase, II2GExdllCT4 220 – 240 V/380 – 420 V 50 Hz 0.18 kW With PTC, speed control range 1:5

* Three-phase motor according to IEC 60034-1

Motor data sheets can be requested for more information. Versions 265/460V – 60Hz, special motors or special motor flanges are available on request.

Motors less than 0.75 kW and motors designed for speed-controllable operation are not subject to the IE3 standard in compliance with the Ecodesign Directive 2009/125/EC.

Information for use in areas at risk from explosion

Only use pumps with the appropriate labelling in line with the ATEX Directive 2014/34/EC in premises at risk from explosion. Ensure that the explosion group, category and degree of protection specified on the label correspond to or are superior to the conditions prevalent in the intended application.