Plunger Metering Pump Makro/ 5

Capacity range of single head pump: 38 – 6,014 l/h, 320 – 6 bar

The plunger metering pump Makro/ 5 can virtually be used throughout the low-pressure range and its modular construction enables it to be outstandingly adapted to the performance requirements of the respective application.

Powerful, Built to Last With a Plunger

The plunger metering pump MAKRO M5Ka together with the MAKRO hydraulic diaphragm and diaphragm metering pumps form a range of drive mechanisms with stroke lengths of 20 or 50 mm. A wide range of drive versions is available for use in areas at risk from explosion with ATEX certification.

Your benefits

Process reliability:

  • The dosing precision is better than ± 0.5 % within the 10-100 % stroke length range under defined conditions and with correct installation

Excellent flexibility:

  • The modular construction with single and double head versions permits a wide range of applications, with the double head designs (boxer principle) being operated in push-pull mode
  • It is possible to combine up to 4 metering units, even with different pump capacities, in multiple pump systems
  • 5 different gear ratios are available
  • Customised designs are available on request

Technical Details

  • Stroke length: 0-50 mm
  • Rod force: 10000 N
  • Stroke length adjustment range: 0 – 100%
  • Stroke length adjustment: manually using manual adjustment wheel and scaled display in 0.5% increments (optionally with electric control drive)
  • The dosing precision is better than ± 0.5 % within the 10 – 100% stroke length range under defined conditions and with correct installation. Observe the information in the operating instructions
  • High-performance ceramic-coated stainless steel plunger
  • Wetted materials: Stainless steel 1.4571, special materials are available on request
  • A wide range of power end/drive versions is available: Three-phase standard AC motors, motors for use in areas at risk from explosion and different flange designs for use in customer-specific motors
  • Degree of protection: IP 55
  • Salt water-resistant, acrylic resin-coated cast aluminium housing
  • For safety reasons, provide suitable overflow equipment with all plunger metering pumps during installation
  • Design in compliance with API 675 among others

Control of MAKRO M5Ka metering pumps

Stroke length controller MAKRO M5Ka

Control drive consisting of an actuator with servomotor and integral microprocessor controller for stroke length adjustment via a standard signal. Actuating period approx. 100 sec for 100% stroke length, equipped with 2 limit switches for min./max. position, degree of protection: IP 54. Electrical connection 230 V (±10%), 50/60 Hz, approx. 40 W mechanical stroke length display fitted on the Makro/ 5 drive.

Special voltage/higher degrees of protection/explosion protection available on request.

Design with:

0/4-20 mA standard current input (corresponds to stroke length 0-100%); internal switch-over for manual/automatic operation, key switch for stroke adjustment in manual mode. 0/4-20 mA actual value output for remote display.

Stroke sensor with Namur signal

Mounting on the crank drive mechanism of the Makro/ 5 gearbox. For precise measurement of each metering stroke, comprising electronic cams and inductive proximity switches, switching signal according to Namur. In combination with electronic pre-selection meters suitable for batch metering or proportional metering in conjunction with proportional control.

Retrospective fitting only possible in the factory.

Approved for explosion protection operation with degree of protection EEx ia II C T6.

Technical Data

Type Capacity at max. back pressure with 1500 rpm motor at 50 Hz Capacity at max. back pressure with 1800 rpm motor at 60 Hz Suction lift Connector Suction/Discharge Side Shipping weight Plunger Ø
  Max. stroke rate   Max. stroke rate
l/h bar ml/stroke Strokes/min l/h psi gph (US) Strokes/min m WC G-DN kg mm
3200066 66 320 11 103 78 4,640 21 123 3.0 Rp 1/4–8 300 17
3200038 38 320 11 60 44 4,640 12 71 3.0 Rp 1/4–8 300 17
3200048 48 320 11 75 56 4,640 15 89 3.0 Rp 1/4–8 300 17
3200085 85 320 11 133 101 4,640 27 159 3.0 Rp 3/8–10 300 17
3200100 100 320 11 156 3.0 Rp 3/8–10 300 17
1700184 184 170 21 156 3.0 G 1–15 300 23
2160157 157 216 21 133 187 3,132 49 159 3.0 Rp 3/8–10 300 23
2400070 70 240 21 60 82 3,480 22 71 3.0 Rp 3/8–10 300 23
2400088 88 240 21 75 104 3,480 27 89 3.0 Rp 3/8–10 300 23
2400121 121 240 21 103 144 3,480 38 123 3.0 Rp 3/8–10 300 23
1000314 314 100 35 156 3.0 G 1 1/4–20 302 30
1270267 267 127 35 133 319 1,842 84 159 3.0 G 1 1/4–20 302 30
1400120 120 140 35 60 142 2,030 38 71 3.0 G 1–15 302 30
1400151 151 140 35 75 179 2,030 47 89 3.0 G 1–15 302 30
1400207 207 140 35 103 247 2,030 65 123 3.0 G 1–15 302 30
0800214 214 80 63 60 253 1,160 67 71 3.0 G 1 1/4–20 303 40
0560558 558 56 63 156 3.0 G 1 1/2–25 303 40
0700476 476 70 63 133 569 1,015 150 159 3.0 G 1 1/2–25 303 40
0800268 268 80 63 75 318 1,160 84 89 3.0 G 1 1/4–20 303 40
0800368 368 80 63 103 439 1,160 116 123 3.0 G 1 1/4–20 303 40
0350872 872 35 98 156 3.0 G 1 1/2–25 303 50
0450744 744 45 98 133 889 653 235 159 3.0 G 1 1/2–25 303 50
0500335 335 50 98 60 396 725 105 71 3.0 G 1 1/2–25 303 50
0500419 419 50 98 75 497 725 131 89 3.0 G 1 1/2–25 303 50
0500576 576 50 98 103 687 725 181 123 3.0 G 1 1/2–25 303 50
0251257 1,257 25 141 156 3.0 G 2–32 311 60
0301071 1,071 30 141 133 1,280 435 338 159 3.0 G 2–32 311 60
0350483 483 35 141 60 571 508 151 71 3.0 G 1 1/2–25 311 60
0350604 604 35 141 75 716 508 189 89 3.0 G 1 1/2–25 311 60
0350829 829 35 141 103 989 508 261 123 3.0 G 2–32 311 60
0250658 658 25 192 60 778 363 206 71 3.0 G 2–32 311 70
0181710 1,710 18 192 156 3.0 G 2 1/4–40 311 70
0231458 1,458 23 192 133 1,743 334 460 159 3.0 G 2 1/4–40 311 70
0250822 822 25 192 75 975 363 258 89 3.0 G 2–32 311 70
0251129 1,129 25 192 103 1,348 363 356 123 3.0 G 2–32 311 70
0161665 1,665 16 284 103 1,988 232 525 123 3.0 G 2 1/4–40 317 85
0160970 970 16 284 60 1,147 232 303 71 3.0 G 2 1/4–40 317 85
0161212 1,212 16 284 75 1,438 232 380 89 3.0 G 2 1/4–40 317 85
0162150 2,150 16 284 133 2,570 232 679 159 3.0 G 2 3/4–50 317 85
0162522 2,522 16 284 156 3.0 G 2 3/4–50 317 85
0103491 3,491 10 393 156 3.0 G 2 3/4–50 331 100
0121343 1,343 12 393 60 1,589 174 420 71 3.0 G 2 3/4–50 331 100
0121678 1,678 12 393 75 1,991 174 526 89 3.0 G 2 3/4–50 331 100
0122305 2,305 12 393 103 2,752 174 727 123 3.0 G 2 3/4–50 331 100
0122977 2,977 12 393 133 3,558 174 940 159 3.0 G 2 3/4–50 331 100
0063896 3,896 6 664 103 4,652 87 1,229 123 3.0 G 2 1/2–65 350 130
0062269 2,269 6 664 60 2,684 87 709 71 3.0 G 2 1/2–65 350 130
0062837 2,837 6 664 75 3,366 87 889 89 3.0 G 2 1/2–65 350 130
0065031 5,031 6 664 133 6,014 87 1,589 159 3.0 G 2 1/2–65 350 130
0066000 6,000 6 664 156 3.0 G 2 1/2–65 350 130

Materials in Contact with the Medium

Type Identity code of material Dosing head Connection on suction/discharge side Valve seat/seals Valve balls Plungers
M5Ka DN 8 – DN 10 Stainless steel 1.4571/1.4404 Stainless steel 1.4571/1.4404 Stainless steel/PTFE Oxide ceramic Stainless steel/ceramic
M5Ka DN 15 – DN 25 Stainless steel 1.4571/1.4404 Stainless steel 1.4581 PTFE Stainless steel 1.4401 Stainless steel/ceramic
M5Ka DN 32 – DN 65 Stainless steel 1.4571/1.4404 Stainless steel 1.4581/1.4404 PTFE Stainless steel 1.4404 (plate/spring) Stainless steel/ceramic

The permissible priming pressure on the suction side is approximately 50% of the max. permitted back pressure.

Motor Data

Identity code specification Power supply Remarks
S 3-phase, IP 55* 230 V/400 V 50 Hz 3 kW
R 3-phase, IP 55* 230 V/400 V 50/60 Hz 3 kW With PTC, speed control range 1:5
V0 3-phase, IP 55 400 V 50 Hz 3 kW Variable speed stroke control motor with integrated frequency converter
L2 3-phase, II 2G Ex de IIC T4 Gb 230 V/400 V 50 Hz 4 kW With PTC, speed control range 1:5
P2 3-phase, II 2G Ex de IIC T4 265 V/460 V 60 Hz 4 kW With PTC, speed control range 1:5

* Three-phase motor according to IEC 60034-1

Motor data sheets can be requested for more information. Versions 265/460V – 60Hz, special motors or special motor flanges are available on request.

Information for use in areas at risk from explosion

Only use pumps with the appropriate labelling in line with the ATEX Directive 2014/34/EC in premises at risk from explosion. Ensure that the explosion group, category and degree of protection specified on the label correspond to or are superior to the conditions prevalent in the intended application.