Electrolysis System CHLORINSITU IIa XL

Output 5 – 45 kg/h of chlorine

CHLORINSITU IIa XL is the tubular cell electrolysis system for on-site production of large quantities of hypochlorite. Users cannot fail to be impressed by its ease of operation and outstanding efficiency combined with optimum process stability for the reliable disinfection of large volumetric flows.

High-Performance Open Cell Electrolysis

The new CHLORINSITU IIa XL is specially developed to meet the requirements of large-capacity in-situ potable water disinfection. Based on the robust tubular cells, the system is a modular system for the safe production of hypochlorite solution from a diluted salt solution. Thanks to its precise production and optimised cell design, it achieves a high turnover of salt at a concentration of 8 g/l in the final product. The certified safety concept ensures the safe extraction of hydrogen and maximum operating safety. The CIIa XL is combined with the necessary modules, depending on the needs of the project, and is adapted as best as possible to the conditions on-site.

Your Benefits

  • Sole use of salt as the raw material
  • Very long service lives due to minimal maintenance and robust technology
  • Proven cell design with increased efficiency, only 3.2 kg NaCl/kg free chlorine
  • Modular design
  • Easy accessibility
  • Certified safety

Technical Details

Modular electrolysis system with project-specific additional components:

  • Softener system
  • Salt dissolving and supply
  • Pre-dilution unit
  • Cooling unit to optimise the temperature in the feed water
  • Rectifier
  • Process control
  • Product storage tank
  • Metering stations

Technical Data

Output Number of electrolysis cells Product volume (NaOCl) Max. salt consumption
kg/h kg/d   l/h m3/d kg/h kg/d
5 120 1 625 15 16 384
7.5 180 1 935 22.5 24 576
10 240 2 1,250 30 32 768
15 360 2 1,875 45 48 1,152
20 480 3 2,500 60 64 1,536
22.5 540 3 2,810 67.5 72 1,728
30 720 4 3,750 90 96 2,304
45 1,080 6 5,625 135 144 3,456

All figures apply for 20 °C ambient temperature and 10-20 °C feed water. The performance is affected by the temperature and quality of the water and salt.

System availability: 24 h/d
Salt usage: 3.2 kg/kg chlorine
Energy efficiency: 4.2 (DC) / 4.9 (AC) kWh/kg chlorine
Product concentration: 8 g/l (0.8 % ±0.05) chlorine
pH value of product (approx.): 9.5
Salt specifications: CHLORINSITU salt, salt tablets or salt with a grain size of ≥ 6 mm, min. 99.4 % NaCl, max. 0.05 % insoluble substances, max. 10 mg/kg iron, max. 10 mg/kg manganese, max. 100 mg/kg calcium + magnesium
Inlet water temperature: 10…25 °C (lower/higher temperatures require a heater/chiller)
Water supply (drinking water quality) 2 bar < pressure < 5 bar and flow > 50 l/min; softened water, hardness < 0.05 °dH. A system separator or interim storage tank are needed for direct connection to the water supply (refer to local regulations)
Ambient conditions: Non-condensing, non-corrosive and dust-free ambient air in the installation room
Salt dissolving tank: Customer-specific