Electrolysis System CHLORINSITU III

Output 100 – 10,000 g/h of chlorine

Ultra-pure or low-chloride and low-chlorate sodium hypochlorite requires specialist plant engineering. The electrolysis system CHLORINSITU III is the solution for you.

Chlorine and Sodium Hydroxide Made From Common Salt. Directly On-Site.

Electrolysis systems of type CHLORINSITU III generate sodium hypochlorite with a concentration of approximately 25 g/l with minimal entrainment of sodium chloride (85 % yield) from the membrane cell into the finished product. The final sodium hypochlorite solution can be metered, as required, by separate metering pumps. Due to its moderate pH value of 9.5 – 10, it affects the pH of the treated water significantly less than if conventional sodium hypochlorite (pH 12 – 13.5) were used. Less acid is therefore used to adjust the pH value, enabling savings of up to 70 %.

Your Benefits

  • Sodium hypochlorite solution low in chloride and chlorate with a high chlorine concentration (25 g/l free chlorine)
  • Minimal acid consumption for pH correction, enabling savings of up to 70 %
  • Safe system control with remote diagnosis by Remote Control Engineer
  • Excellent service life of the membrane cells thanks to a constant vacuum
  • A frequency-controlled centrifugal pump maintains the vacuum constant in the enclosed anode area
  • Excellent operating safety due to its design as a negative pressure system

Technical Details

  • Modern PLC with large illuminated display
  • Integrated Remote Control Engineer for remote diagnosis and troubleshooting
  • Storage tank for multiple points of injection

Technical Data

Power supply 3 x 400 V (VAC/3P/N/PE/50 Hz)

Type/output Fuse Power uptake Salt consumption Max. consumption of process water Max. consumption of cooling water Dimensions L x W x H Brine tank Recommended capacity storage tank
g/h A kW kg/d l/h l/h mm l l
100 3 x 16 1.10 5 4 80 1,250 x 600 x 1,550 210 200
200 3 x 16 1.50 10 8 80 1,250 x 600 x 1,550 210 300
300 3 x 16 1.90 15 12 100 1,250 x 600 x 1,550 210 400
400 3 x 16 2.30 20 16 100 1,250 x 600 x 1,550 210 500
500 3 x 16 2.70 25 20 125 1,250 x 600 x 1,550 210 600
600 3 x 20 3.10 30 24 125 1,650 x 600 x 2,000 400 700
750 3 x 25 3.70 35 30 150 1,650 x 600 x 2,000 400 800
1000 3 x 25 4.70 50 40 150 1,650 x 600 x 2,000 400 1200
1250 3 x 35 5.70 60 50 150 1,650 x 600 x 2,000 400 1500
1500 3 x 35 6.70 70 60 180 1,650 x 600 x 2,000 400 1700
1750 3 x 35 7.70 80 70 180 1,650 x 600 x 2,000 400 2000
2000 3 x 50 8.70 100 80 200 1,750 x 1,200 x 2,000 520 2200
2500 3 x 63 10.70 125 100 250 1,750 x 1,200 x 2,000 520 3000
3000 3 x 63 12.70 150 120 300 1,750 x 1,200 x 2,000 520 3300
3500 3 x 80 14.70 175 140 350 1,750 x 1,200 x 2,000 520 4000
5000 3 x 90 20.70 250 200 500 3,100 x 1,800 x 2,070 1,150 5800
7000 3 x 100 29.40 350 280 700 3,100 x 1,800 x 2,070 1,150 6000
8500 3 x 130 35.70 425 340 850 4,300 x 1,800 x 2,070 1,150 7500
10000 3 x 160 40.70 500 400 1000 4,300 x 1,800 x 2,070 1,150 11000

Scope of delivery

Electrolysis systems of type CHLORINSITU III are mounted ready-wired on a powder-coated stainless steel frame with a controller (PLC) in the control cabinet. They include a Remote Control Engineer for remote diagnosis and troubleshooting, integrated water softener system, membrane electrolysis cells, hydrogen bleed system and separate salt dissolving tanks with level monitoring unit. Dynamic level control to monitor the storage tank for sodium hypochlorite to be provided on-site. A chlorine gas detector and automatic monitoring of water hardness downstream of the softening system come as standard with systems producing more than 600 g/h.

Remark

Electrolysis systems of type CHLORINSITU III, V and V Plus are available and planned to meet customer specifications. This is true both for the system documentation and the subsequent supply of spare parts and maintenance.